H2S Lab Process Analyzer – XLE 105-3 LAB
One Great Product in Three Styles to Fit Your Every Need in an H2S Process Analyzer
The “TRI” analyzer was uniquely designed to measure the 3 different levels of H2S in a laboratory environment. The analyzer measures the H2S from 0-100PPM then automatically switches to a mid-range of 0-3000PPM and then to a high range of 0-5%. TAC specializes in customizing our products for each application.
Truly the heart of the system; the TAC electrochemical sensor recognizes the presence of H2S in just seconds. The sensor typically lasts one year and can be changed in just seconds. Calibration is simple and can be done is less than 6 minutes. An LED indicator on the front panel tells you when the analyzer is in the calibration mode.
TAC specializes in customizing our products to fit your needs. The Lab Unit can also be ordered to measure two different ranges. For Example: Low Range 0-100 PPM and automatically switch to a High Range 100-5000 PPM.
Full Technical Support
You will find the analyzers are easy to maintain. Technical support is available via phone or in person by one of our service technicians.

Downloads
Application Worksheet
XLE 105-3 LAB Features
Front Loading Sensor
Minimize maintenance downtime. Our updated design allows operators to quickly and easily replace H2S sensors by removing just one thumbscrew.

“Sensor Weak” Alert
Stay ahead of maintenance schedules. The analyzer automatically displays a “Sensor Weak” alert when H2S sensors reach 75% capacity, giving operators ample time to swap them out before failure.

On-Screen Historical Trend
Monitor performance at a glance. The display features a live, visual graph showing the historical trend of H2S readings over the previous hour.

Automated “Flow Fail” Alerts
Ensure your sample is secure. The display immediately reads “Flow Fail” if regulators or flow meters malfunction, or if the sample line to the analyzer becomes obstructed.

SD Card Data Logging & Custom IDs
Easily track and export your data. Store historical calibration and alarm data directly to an SD card. You can assign a custom Name or ID to each analyzer, which automatically carries over when downloading your data to a spreadsheet.

XLE 105-3 LAB Specs
Detection Method:
Electro-chemical (Estimated life: 1 Year)
Ranges: Customer to specify a range and can be field programmable to alarm at any desired set point. (% level is also available)
- H2S 0-10,25,50 and 100PPM. (% level is also available)
Response Time:
< 60 Seconds
Sample Input Pressure:
Inlet 10 +/-2 PSIG
Power Input:
110V AC
12V DC
24V DC
Instrument Repeatability:
+/- 2%
Instrument Accuracy:
+/-5% of the Full Scale
Current Draw: < 1 A
Standard:
Self Powered 4-20 mA Output
Communications Output:
Loop Powered 4-20 mA
Modbus/Ethernet
Data Logging Capabilities
Media