H2O Online Process Analyzer – XLE 105-2


H2O Monitoring Made Simple

Choose Texas Analytical Controls for reliable, economical H2O monitoring. With a unique H2O sensor cross interference, the TAC analyzer is your first choice for reliable H2O monitoring to protect pipelines from corrosion.

Easy to Operate and Maintain

The TAC analyzer outshines the competition when it comes to ease of operation and maintenance.

Sensors typically last 2 years and can be changed in just a few minutes.  No special tools are required.

Calibration is performed at the TAC factory prior to shipping.  Field calibration is not required.

Full Technical Support

You will find the analyzers are easy to maintain.  Technical support is available via phone or in person by one of our service technicians.

TAC H2O Online Process Analyzer – XLE 105-2 front view.

Downloads


Application Worksheet

XLE 105-2 Features


On-Screen Historical Trend

Monitor performance at a glance. The display features a live, visual graph showing the historical trend of H2S readings over the previous hour.

H2S Analyzer historical trending chart displayed on-screen as a line graph

Automated “Flow Fail” Alerts

Ensure your sample is secure. The display immediately reads “Flow Fail” if regulators or flow meters malfunction, or if the sample line to the analyzer becomes obstructed.

Flow Fail displayed on screen

SD Card Data Logging & Custom IDs

Easily track and export your data. Store historical calibration and alarm data directly to an SD card. You can assign a custom Name or ID to each analyzer, which automatically carries over when downloading your data to a spreadsheet.

H2S Analyzer SD Card Holder location diagram

XLE 105-2 Specs


Range: Customer to specify a range and can be field programmable to alarm at any desired set point. Typical ranges:

  • H2O 0-10, 0-20 LBS (other ranges available)

Detection Method: H2O- Thermoset Polymer Sensor (Estimated life: 2 Years)


Calibration: Field Calibration is not required


Communications Output: 4-20 mA (Self Powered), Modbus
(See Customizations for additional options)


Sample Input Pressure: Inlet 10 +/- 2 PSIG


Response Time: < 60 Seconds


Instrument Accuracy: +/-5% of the Full Scale


Instrument Repeatability: +/- 2%


Current Draw: < 1 A


Operating Temperature: -20°C to 50°C; -40°F to 122°F


Dimensions: 6.3″ x 3.5″ x 2.4″

XLE 105-2 Customizations


Range:

H20

0-10 LBS
0-20 LBS

(Customer specifies desired range in PPM or %)


Communications Output:

4-20 Self Powered (Standard)
4-20 Loop Powered
1-5 VDC
Modbus via RTU (Standard)
Modbus via TCP/IP


Power Input:

12 VDC
24 VDC
110 VAC
Solar Panels


Alarm Relays:

Two Independent SPDT Relays for Low and High Alarm
Relays are set for FAIL SAFE
Alarm Setpoints, Latching, and Non Latching are PLC Programmable
Relay Ratings:
2.5A @ 125v AC
4.0A @ 24v DC


Alarm Delay: An Alarm Delay is PLC Programmable, the delay can be set for 0-90 minutes.


Shut-In Valve: Pneumatic solenoid valve or relays to control an external shut-in valve


Standard Enclosure: NEMA 4X powder coated (Dimensions: 12” x 10” x 6” Weight: 20 pounds)


Explosion Proof Enclosure: Explosion proof, suitable for Class 1, Division 1, Groups B, C, and D. (Dimensions: 18” x 16” x 12” Weight: 45 pounds)