H2O Online Process Analyzer – XLE 105-2
H2O Monitoring Made Simple
Choose Texas Analytical Controls for reliable, economical H2O monitoring. With a unique H2O sensor cross interference, the TAC analyzer is your first choice for reliable H2O monitoring to protect pipelines from corrosion.
Easy to Operate and Maintain
The TAC analyzer outshines the competition when it comes to ease of operation and maintenance.
Sensors typically last 2 years and can be changed in just a few minutes. No special tools are required.
Calibration is performed at the TAC factory prior to shipping. Field calibration is not required.
Full Technical Support
You will find the analyzers are easy to maintain. Technical support is available via phone or in person by one of our service technicians.

Downloads
Application Worksheet
XLE 105-2 Features
On-Screen Historical Trend
Monitor performance at a glance. The display features a live, visual graph showing the historical trend of H2S readings over the previous hour.

Automated “Flow Fail” Alerts
Ensure your sample is secure. The display immediately reads “Flow Fail” if regulators or flow meters malfunction, or if the sample line to the analyzer becomes obstructed.

SD Card Data Logging & Custom IDs
Easily track and export your data. Store historical calibration and alarm data directly to an SD card. You can assign a custom Name or ID to each analyzer, which automatically carries over when downloading your data to a spreadsheet.

XLE 105-2 Specs
Range: Customer to specify a range and can be field programmable to alarm at any desired set point. Typical ranges:
- H2O 0-10, 0-20 LBS (other ranges available)
Detection Method: H2O- Thermoset Polymer Sensor (Estimated life: 2 Years)
Calibration: Field Calibration is not required
Communications Output: 4-20 mA (Self Powered), Modbus
(See Customizations for additional options)
Sample Input Pressure: Inlet 10 +/- 2 PSIG
Response Time: < 60 Seconds
Instrument Accuracy: +/-5% of the Full Scale
Instrument Repeatability: +/- 2%
Current Draw: < 1 A
Operating Temperature: -20°C to 50°C; -40°F to 122°F
Dimensions: 6.3″ x 3.5″ x 2.4″
XLE 105-2 Customizations
Range:
H20
0-10 LBS
0-20 LBS
(Customer specifies desired range in PPM or %)
Communications Output:
4-20 Self Powered (Standard)
4-20 Loop Powered
1-5 VDC
Modbus via RTU (Standard)
Modbus via TCP/IP
Power Input:
12 VDC
24 VDC
110 VAC
Solar Panels
Alarm Relays:
Two Independent SPDT Relays for Low and High Alarm
Relays are set for FAIL SAFE
Alarm Setpoints, Latching, and Non Latching are PLC Programmable
Relay Ratings:
2.5A @ 125v AC
4.0A @ 24v DC
Alarm Delay: An Alarm Delay is PLC Programmable, the delay can be set for 0-90 minutes.
Shut-In Valve: Pneumatic solenoid valve or relays to control an external shut-in valve
Standard Enclosure: NEMA 4X powder coated (Dimensions: 12” x 10” x 6” Weight: 20 pounds)
Explosion Proof Enclosure: Explosion proof, suitable for Class 1, Division 1, Groups B, C, and D. (Dimensions: 18” x 16” x 12” Weight: 45 pounds)