H2S Online Process Analyzer – XLE 105-1


H2S Monitoring Made Simple

Choose Texas Analytical Controls for reliable, economical H2S monitoring. With two H2S sensors, the TAC analyzer is your first choice for reliable H2S monitoring in the field. If the output of one sensor fails, you can easily disable it.  The analyzer will continue to operate reliably, assuring you of consistent H2S monitoring over time.

Easy to Operate and Maintain

The TAC analyzer outshines the competition when it comes to ease of operation and maintenance. Sensors typically last a full year and can be changed in just a few minutes.  No special tools are required.

Calibration is simple and can be done in less than six minutes. Calibration can be set up to occur automatically, reducing the time required in the field, or can be performed manually.

Full Technical Support

You will find the analyzers are easy to maintain.  Technical support is available via phone or in person by one of our service technicians.

TAC Controls XLE 105-1 H2S On-Line Process Analyzer with control panel door open.

Downloads


XLE 105-1 H2S Analyzer Spec Sheet PDF

Flow Diagram- H2S

Application Worksheet

XLE 105-1 Features


Front Loading Sensor

Minimize maintenance downtime. Our updated design allows operators to quickly and easily replace H2S sensors by removing just one thumbscrew.

H2S Analyzer quick change sensor panel with single thumb screw.

“Sensor Weak” Alert

Stay ahead of maintenance schedules. The analyzer automatically displays a “Sensor Weak” alert when H2S sensors reach 75% capacity, giving operators ample time to swap them out before failure.

Sensor Weak warning shown on H2S Analyzer screen

In-Line Bump Testing

Verify your readings without the hassle of removing the sample line. This quick check saves operators from having to perform a full, 10-minute calibration.

H2S Analyzer screen showing Bump Test in progress

On-Screen Historical Trend

Monitor performance at a glance. The display features a live, visual graph showing the historical trend of H2S readings over the previous hour.

H2S Analyzer historical trending chart displayed on-screen as a line graph

Automated “Flow Fail” Alerts

Ensure your sample is secure. The display immediately reads “Flow Fail” if regulators or flow meters malfunction, or if the sample line to the analyzer becomes obstructed.

Flow Fail displayed on screen

SD Card Data Logging & Custom IDs

Easily track and export your data. Store historical calibration and alarm data directly to an SD card. You can assign a custom Name or ID to each analyzer, which automatically carries over when downloading your data to a spreadsheet.

H2S Analyzer SD Card Holder location diagram

XLE 105-1 Specs


Range: Customer to specify a range and can be field programmable to alarm at any desired set point. (% level is also available)

  • H2S 0-10,25,50 and 100PPM. (% level is also available)

Detection Method: Electro-chemical (Estimated life: 1 Year)


Calibration: An LED indicator on the front panel illuminates when the analyzer is in calibration mode. Display shows “Cal Complete” after a successful calibration. Calibration can be performed Automatically or Manually. Watch How to Calibrate Our Analyzers video below for details.


Communications Output: – 4-20 mA (Self Powered), Modbus – See Customizations for additional options


Sample Input Pressure: – Inlet 10 +/-2 PSIG


Response Time: – < 60 Seconds


Instrument Accuracy: – +/-5% of the Full Scale


Instrument Repeatability: – +/- 2%


Current Draw: < 1 A


Operating Temperature: -20°C to 50°C; -40°F to 122°F

XLE 105-1 Customizations


Range:

Standard

0-5 PPM
0-10 PPM
0-20 PPM
0-50 PPM
0-100 PPM

Medium

0-500 PPM
0-1000 PPM
0-3000 PPM

High

0-5000 PPM
0-10000 PPM

Percent

0-2%
0-5 %
0-10%
0-20 %

(Customer specifies desired range in PPM or %)


Communications Output:

4-20 Self Powered (Standard)
4-20 Loop Powered
1-5 VDC
Modbus via RTU (Standard)
Modbus via TCP/IP


Power Input:

12 VDC
24 VDC
110 VAC
Solar Panels


Alarm Relays:

Two Independent SPDT Relays for Low and High Alarm
Relays are set for FAIL SAFE
Alarm Setpoints, Latching, and Non Latching are PLC Programmable
Relay Ratings:
2.5A @ 125v AC
4.0A @ 24v DC


Alarm Delay: An Alarm Delay is PLC Programmable, the delay can be set for 0-90 minutes.


Shut-In Valve: Pneumatic solenoid valve or relays to control an external shut-in valve


Standard Enclosure: NEMA 4X powder coated (Dimensions: 12” x 10” x 6” Weight: 20 pounds)


Explosion Proof Enclosure: Explosion proof, suitable for Class 1, Division 1, Groups B, C, and D. (Dimensions: 18” x 16” x 12” Weight: 45 pounds)

Media


TAC Controls XLE 105-1 H2S On-Line Process Analyzer with control panel door open.
H2S Online Analyzer in high range configuration

How to Calibrate our H2S Process Analyzers

How to Replace H2S Sensors