O2 Online Process Analyzer – XLE 105-3
O2 Monitoring Made Simple
The Texas Analytical Controls’ Model XLE 302 Series O2 analyzers are extremely fast and accurate instruments for detecting and quantifying oxygen levels in process streams. XLE302 Series employs advanced technology in every area of operation from the sensor to diagnostics. The dedication to technological progress is the reason our analyzers are the lowest maintenance and most cost-effective line of analyzers available.
Easy to Operate and Maintain
The TAC analyzer outshines the competition when it comes to ease of operation and maintenance. Our O2 Sensors typically last a full year and can be changed in just a few minutes. No special tools are required.
Full Technical Support
You will find the analyzers are easy to maintain. Technical support is available via phone or in person by one of our service technicians.

Downloads
XLE 105-3 Spec Sheet PDF
Application Worksheet
XLE 105-3 Features
Front Loading Sensor
Minimize maintenance downtime. Our updated design allows operators to quickly and easily replace O2 sensors by removing just one thumbscrew.

“Sensor Weak” Alert
Stay ahead of maintenance schedules. The analyzer automatically displays a “Sensor Weak” alert when O2 sensors reach 75% capacity, giving operators ample time to swap them out before failure.

In-Line Bump Testing
Verify your readings without the hassle of removing the sample line. This quick check saves operators from having to perform a full, 10-minute calibration.

On-Screen Historical Trend
Monitor performance at a glance. The display features a live, visual graph showing the historical trend of O2 readings over the previous hour.

Automated “Flow Fail” Alerts
Ensure your sample is secure. The display immediately reads “Flow Fail” if regulators or flow meters malfunction, or if the sample line to the analyzer becomes obstructed.

SD Card Data Logging & Custom IDs
Easily track and export your data. Store historical calibration and alarm data directly to an SD card. You can assign a custom Name or ID to each analyzer, which automatically carries over when downloading your data to a spreadsheet.

XLE 105-3 Specs
Range: Customer to specify a range and can be field programmable to alarm at any desired set point.
Detection Method: Micro Fuel Cell (Estimated life: 1 Year)
Calibration: An LED indicator on the front panel illuminates when the analyzer is in calibration mode. Display shows “Cal Complete” after a successful calibration. Calibration can be performed Automatically or Manually. Watch How to Calibrate Our Analyzers video below for details.
Communications Output: 4-20 mA (Self Powered), Modbus
Sample Input Pressure: Inlet 10 +/-2 PSIG
Response Time: < 60 Seconds
Instrument Accuracy: +/-5% of the Full Scale
Instrument Repeatability: +/- 2%
Current Draw: < 1 A
Operating Temperature: -20°C to 50°C; -40°F to 122°F
Media

