H2S Portable Analyzer- XLE 105-1 PAL R


High-Performance H2S Monitoring for Natural Gas Pipelines

The PAL H2S Analyzer is an economical, portable solution engineered to monitor hydrogen sulfide levels from 0–100 ppm in natural gas pipelines via a reliable one-year electro-chemical sensor. Ideal for quick spot checks or extended on-site monitoring, the instrument features fast, straightforward calibration to ensure consistent field readiness.

Integrated Sampling System and Smart Data Logging

Each unit includes a built-in stainless steel sampling system equipped with a 3000 PSIG regulator, a 1500 PSIG liquid-blocking membrane filter, and Swagelok 1/8″ quick-disconnect fittings. For effortless tracking, an integrated SD card logs location-specific data that can be exported directly into Excel.

Technical Specifications and Dependable Field Support

Housed in a compact 9-pound enclosure, this rugged analyzer delivers ±2% accuracy within 30 seconds and provides 10 hours of battery life on a quick 3-hour charge. Maintenance is simple with automated “Sensor Weak” screen alerts and full technical support available directly from TAC by phone, online, or in the field.

H2S Portable Analyzer XLE-105-1-PAL-R

Downloads


XLE 105-1 PAL-R Spec Sheet PDF

Application Worksheet

XLE 105-1 PAL R Specs


Range: Customer to specify a range and can be field programmable to alarm at any desired set point. (% level is also available)

  • H2S 0-10,25,50 and 100PPM. (% level is also available)

Detection Method: Electro-chemical (Estimated life: 1 Year)


Calibration: An LED indicator on the front panel illuminates when the analyzer is in calibration mode. Display shows “Cal Complete” after a successful calibration. Calibration can be performed Automatically or Manually. Watch How to Calibrate Our Analyzers video below for details.


Communications Output: 4-20 mA (Self Powered), Modbus – See Customizations for additional options


Sample Input Pressure:

Inlet 10 +/-2 PSIG


Response Time: < 60 Seconds


Instrument Accuracy:

+/-5% of the Full Scale


Instrument Repeatability: – +/- 2%


Current Draw: < 1 A


Operating Temperature:

-20°C to 50°C; -40°F to 122°F

XLE 105-1 PAL R Customizations


Range:

Standard

0-5 PPM
0-10 PPM
0-20 PPM
0-50 PPM
0-100 PPM

Medium

0-500 PPM
0-1000 PPM
0-3000 PPM

High

0-5000 PPM
0-10000 PPM

Percent

0-2%
0-5 %
0-10%
0-20 %

(Customer specifies desired range in PPM or %)


Communications Output:

4-20 Self Powered (Standard)
4-20 Loop Powered
1-5 VDC
Modbus via RTU (Standard)
Modbus via TCP/IP


Power Input:

12 VDC
24 VDC
110 VAC
Solar Panels


Alarm Relays:

Two Independent SPDT Relays for Low and High Alarm
Relays are set for FAIL SAFE
Alarm Setpoints, Latching, and Non Latching are PLC Programmable
Relay Ratings:
2.5A @ 125v AC
4.0A @ 24v DC


Alarm Delay: An Alarm Delay is PLC Programmable, the delay can be set for 0-90 minutes.


Shut-In Valve: Pneumatic solenoid valve or relays to control an external shut-in valve


Standard Enclosure: NEMA 4X powder coated (Dimensions: 12” x 10” x 6” Weight: 20 pounds)


Explosion Proof Enclosure: Explosion proof, suitable for Class 1, Division 1, Groups B, C, and D. (Dimensions: 18” x 16” x 12” Weight: 45 pounds)