H2S Portable Analyzer – XLE 105-1 PAL
H2S Monitoring Made Simple
TAC is proud to introduce our H2S Portable Analyzer. Designed from customer feedback, it is small, lightweight and easy to use. Housed in a rugged carrying case, its purpose is to allow operators to spot check the levels of H2S in their pipelines.
The unit has a 10-hour battery life and a self-powered 4-20mA output and data logging capabilities, allowing it to be left on location for short periods. As always TAC is willing to customize it to fit your needs.
Full Technical Support
You will find the analyzers are easy to maintain. Technical support is available via phone or in person by one of our service technicians.

Downloads
XLE 105-1 PAL Spec Sheet PDF
Application Worksheet
XLE 105-1 PAL Specs
Range: Customer to specify a range and can be field programmable to alarm at any desired set point. (% level is also available)
- H2S 0-10,25,50 and 100PPM. (% level is also available)
Detection Method:
Electro-chemical (Estimated life: 1 Year)
Calibration: An LED indicator on the front panel illuminates when the analyzer is in calibration mode. Display shows “Cal Complete” after a successful calibration. Calibration can be performed Automatically or Manually. Watch How to Calibrate Our Analyzers video below for details.
Communications Output:
4-20 mA (Self Powered)
Modbus
(See Customizations for additional options)
Sample Input Pressure:
Inlet 10 +/-2 PSIG
Response Time:
< 60 Seconds
Instrument Accuracy:
+/-5% of the Full Scale
Instrument Repeatability:
+/- 2%
Current Draw: < 1 A
Operating Temperature:
-20°C to 50°C; -40°F to 122°F
XLE 105-1 PAL Customizations
Range:
Standard
0-5 PPM
0-10 PPM
0-20 PPM
0-50 PPM
0-100 PPM
Medium
0-500 PPM
0-1000 PPM
0-3000 PPM
High
0-5000 PPM
0-10000 PPM
Percent
0-2%
0-5 %
0-10%
0-20 %
(Customer specifies desired range in PPM or %)
Communications Output:
4-20 Self Powered (Standard)
4-20 Loop Powered
1-5 VDC
Modbus via RTU (Standard)
Modbus via TCP/IP
Power Input:
12 VDC
24 VDC
110 VAC
Solar Panels
Alarm Relays:
Two Independent SPDT Relays for Low and High Alarm
Relays are set for FAIL SAFE
Alarm Setpoints, Latching, and Non Latching are PLC Programmable
Relay Ratings:
2.5A @ 125v AC
4.0A @ 24v DC
Alarm Delay: An Alarm Delay is PLC Programmable, the delay can be set for 0-90 minutes.
Shut-In Valve: Pneumatic solenoid valve or relays to control an external shut-in valve
Standard Enclosure: NEMA 4X powder coated (Dimensions: 12” x 10” x 6” Weight: 20 pounds)
Explosion Proof Enclosure: Explosion proof, suitable for Class 1, Division 1, Groups B, C, and D. (Dimensions: 18” x 16” x 12” Weight: 45 pounds)